Part Number Hot Search : 
GWACC 74V2T07 G4500 SUR529H TA62004 IRHE7110 4032K14 CA3090
Product Description
Full Text Search
 

To Download CBT-15N Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  automotive circuit breakers for product information and data sheets, visit www .cooperbussmann.com 11 december 11, 2008 consumer aftermarket catalog p a r t n o . b l i s t e r ( a m p s ) p a c k cb211-7 1 / 2 cb211-10 x cb211-15 x cb211-20 x cb211-25 x cb211-30 x p a r t n o . ( a m p s ) cb212-10 cb212-15 cb212-20 cb212-25 cb212-30 p a r t n o . ( a m p s ) o e m n o . mmb-15 12135171 mmb-20 12135072 cb211 type i atm footprint circuit breaker cb212 type ii atm footprint circuit breaker mmb type i wide atm footprint circuit breaker for gm vehicles p a r t n o . d e s c r i p t i o n cb22901-1.5 transorb voltage spike protector cb22902-68 resistor voltage drop device cb22903-6 diode reverse current protector cb22903-6v diode reverse current protector with wing key cooper bussmann offers the industry's largest selection of automotive circuit breakers including both oem-style and fuse-replacement devices. circuit breakers are designed to offer a variety of performance characteristics including three types of reset. (note: always follow the oem's recommendations when replacing circuit breakers. replace only with the same type breaker in aftermarket applications.) type i - automatic reset circuit breaker automatically resets after opening. if the fault still exists, the breaker will continue to cycle between on and off positions until the overload is corrected. these devices are sometimes called "cycling breakers." type i/automatic reset circuit breakers do not address, or correct, overcurrent or fault conditions. they only react by cycling off and on. any overcurrent or fault condition that causes any type i circuit breaker to operate should be corrected as soon as possible. continual vehicle operation under an overcurrent or fault condition (causing the type i circuit breaker to cycle) is not recommended. type ii - modified reset the circuit breaker will remain tripped (in the off position) as long as there's power to the circuit, due to an internal resistor. type ii breakers can be reset by turning off the circuit, or by turning off the ignition switch. these devices are sometimes called "non-cycling breakers." several cooper bussmann type ii breakers feature silver-colored bodies. type iii - manual reset the circuit breaker will remain tripped (in the off position) until an indicator button or lever is manually reset. type iii breakers are also available with a switchable feature, which allows you to use an external button to disable the circuit. cooper bussmann circuit breakers feature our patented fail-safe technology - offering an innovative element design which combines the resetable performance of circuit breakers with the short-circuit protection of a fuse. ? resetable, to work like a normal "cycling" breaker, in low overload conditions. ? under severe overload or short-circuit conditions, the breaker's element will open to prevent damage to the circuit. blade-type breakers cooper bussmann blade-type circuit breakers are available in several reset modes that correspond to sae categories: sae type i (automatic reset), sae type ii (modified reset) and sae type iii (manual reset). all cooper bussmann blade-type circuit breakers utilize carefully designed and manufactured snap-acting thermal elements with precious metal electrical contacts. atm footprint breakers cb211 and cb212 cooper bussmann atm footprint breakers match the blade footprint of atm fuses. ultra-thin, to fit in tight spaces - they're the smallest automotive circuit breakers on the market. cooper bussmann atm footprint breakers comply with sae standard j553. mini devices transorb, resistor and diode vehicle-style electrical protection devices easily install in common atm fuse holders. these circuit protection devices provide voltage and current limiting functionality to vehicle circuitry; and are designed for the on- and off-highway requirements of heavy trucks, rv, construction, agriculture, atv and material handling equipment. ? t r a n s o r b - protects against voltage spikes. clamp rating: 27vdc. power rating: 1500w ? r e s i s t o r - drops circuit voltage. power rating: 5w. resistance: 68 . ? d i o d e - prevents reverse current flow. amp rating: 6a.
for product information and data sheets, visit www .cooperbussmann.com 12 december 11, 2008 consumer aftermarket catalog automotive circuit breakers p a r t n o . ( a m p s ) cb222-10 cb222-15 cb222-20 cb222-25 cb222-30 cb222 type ii atc footprint circuit breakers atc breakers cb221 and cb222 breakers are designed to fit atc style fuse panels. cooper bussmann atc breakers are the thinnest available in the aftermarket. these devices comply with sae standard j553. cb227 complies with sae j553 and sae j1171 for ignition protection. cooper bussmann also offers three atc-style breakers as replacement parts for specific oem applications - acb-20, ccb-25, and fcb-20. p a r t n o . ( a m p s ) cb223-7 1 / 2 cb223-10 cb223-15 cb223-20 cb223-25 cb223-30 p a r t n o . ( a m p s ) o e m n o . bp/ccb-25 4527053 p a r t n o . ( a m p s ) b l i s t e r p a c k cbb-30 x p a r t n o . ( a m p s ) o e m n o . bp/fcb-20 d9ab-14526-ba c o l o r p a r t n o . b l i s t e r t r i - l i n g u a l c o d e ( a m p s ) p a c k b l i s t e r plain ucb-6 x brown ucb-8 x red ucb-10 x blue ucb-15 x x yellow ucb-20 x plain ucb-25 x green ucb-30 x x cbb-30 type ii atc footprint circuit breaker fcb-20 type ii atc footprint circuit breaker for ford vehicles cb223 type iii atc footprint circuit breakers ccb-25 type i atc footprint circuit breaker for chrysler vehicles ucb type i atc footprint circuit breakers ucb breakers feature "snap-off" universal blades that can easily be sized to fit applications where fuse block spacing is tight, or the fuse terminal is recessed. c o l o r p a r t n o . c o d e ( a m p s ) tan cb227-5 moss green cb227-6 brown cb227-7 1 / 2 red cb227-10 blue cb227-15 yellow cb227-20 white cb227-25 green cb227-30 cb227 type iii atc footprint low-profile circuit breakers p a r t n o . ( a m p s ) b l i s t e r p a c k o e m n o . acb-20 x 12040816 acb-20 type i atc footprint circuit breaker for gm vehicles p a r t n o . ( a m p s ) cb221-7 1 / 2 cb221-10 cb221-15 cb221-20 cb221-25 cb221-30 cb221 type i atc footprint circuit breakers
automotive circuit breakers for product information and data sheets, visit www .cooperbussmann.com 13 december 11, 2008 consumer aftermarket catalog p a r t n o . ( a m p s ) cb123-10hb cb123-15hb cb123-20hb cb123-30hb cb123-40hb cb123-50hb p a r t n o . ( a m p s ) cb123-10b cb123-15b cb123-20b cb123-30b cb123-40b cb123-50b p a r t n o . b l i s t e r t r i - l i n g u a l ( a m p s ) p a c k b l i s t e r cbc-8b cbc-10b cbc-15b cbc-20b x cbc-25b x cbc-30b x x cbc-35b x cbc-40b x cbc-50b x cb123-b type iii 10-32 stud-mount circuit breakers with crosswise bracket and cover cb123-hb type iii 10-32 stud-mount circuit breakers with lengthwise bracket and cover cbc type i 10-32 stud-mount circuit breakers cbc-b type i 10-32 stud-mount circuit breakers with crosswise bracket heavy-duty breakers used in many heavy-duty and truck applications. use ring terminals to connect breaker into circuit. cbs are standard-duty and cbc are heavy-duty type breakers. cooper bussmann stud-type circuit breakers feature our patented fail-safe technology, and are available in styles: without bracket; with mounting bracket; waterproof, with mounting bracket and with combination blade and stud terminals. complies with sae standard j553. p a r t n o . ( a m p s ) cb1911-10 cb1911-15 cb1911-20 cb1911-25 cb1911-30 cb1911-35 cb1911-40 cb1911-50 p a r t n o . ( a m p s ) cb1921-10 cb1921-15 cb1921-20 cb1921-25 cb1921-30 cb1911 type i max footprint circuit breakers cb1921 type ii max footprint circuit breakers p a r t n o . ( a m p s ) b l i s t e r p a c k cbf-6 cbf-10 x cbf-15 x cbf-20 x cbf-25 x cbf-30 x cbf-35 cbf-40 x glass tube breakers cbf type ii circuit breakers for use in glass tube fuse holders and blocks cbf circuit breakers can be used to replace glass fuses in 1 / 4 x 1 1 / 4 small dimension fuse blocks. maxi breakers identical in size to maxi-style fuses. the only breakers on the market to match the maxi's footprint and body dimensions. p a r t n o . ( a m p s ) cbc-8 cbc-10 cbc-15 cbc-20 cbc-25 cbc-30 cbc-35 cbc-40 cbc-50
for product information and data sheets, visit www .cooperbussmann.com 14 december 11, 2008 consumer aftermarket catalog automotive circuit breakers p a r t n o . b l i s t e r ( a m p s ) p a c k cbc-10hb cbc-15hb cbc-20hb x cbc-25hb cbc-30hb x cbc-40hb x cbc-50hb x p a r t n o . ( a m p s ) cbc-20bwp cbc-30bwp p a r t n o . ( a m p s ) cbp-20ba cbp-25ba cbp-30ba cbp-40ba cbp-50ba cbc-bwp type i 10-32 stud-mount weatherproof circuit breakers cbc-hb type i 10-32 stud-mount circuit breakers with lengthwise bracket cbp-ba type i 10-32 stud-mount circuit breakers with crosswise bracket p a r t n o . ( a m p s ) cb174-8 cb174-10 cb174-15 cb174-20 cb174-25 cb174-30 p a r t n o . ( a m p s ) cb174b-10 cb174b-15 cb174b-20 cb174b-25 cb174b-30 cb174b-40 panel-mount breakers used in trucks, rvs, boats, buses, etc. offered with 1/4" quick-connect or 90 bent screw terminals. cb174 type iii circuit breakers with 1 / 4 " quick-connect terminals cb174b type iii circuit breakers with 90 5-32 screw terminals p a r t n o . ( a m p s ) cbt-10m cbt-15m cbt-20m cbt-25m cbt-30m p a r t n o . ( a m p s ) cbt-10n CBT-15N cbt-20n cbt-25n cbt-30n p a r t n o . ( a m p s ) cbu-6 cbu-30b cbt-m type ii circuit breakers for mack trucks with 1 / 4 " blades on 1" centers cbt-n type ii circuit breakers for navistar trucks with 1 / 4 " blades on 1.08" centers cbu type i circuit breakers with 1 / 4 " quick-connect terminals on 0.99" centers (30b with crosswise bracket) quick-connect breakers used in trucks, rvs, boats, buses, etc. offered with 1 / 4 " quick-connect or 90 bent screw terminals. cbu-6 cbu-30b
automotive circuit breakers for product information and data sheets, visit www .cooperbussmann.com 15 december 11, 2008 consumer aftermarket catalog p a r t n o . ( a m p s ) cb181f-60 cb181f-110 cb181f-70 cb181f-120 cb181f-80 cb181f-135 cb181f-90 cb181f-150 cb181f-100 p a r t n o . ( a m p s ) cb184f-25 cb184f-80 cb184f-30 cb184f-90 cb184f-35 cb184f-100 cb184f-40 cb184f-110 cb184f-50 cb184f-120 cb184f-60 cb184f-135 cb184f-70 cb184f-150 p a r t n o . ( a m p s ) b l i s t e r p a c k cb185-25 cb185-30 cb185-35 cb185-40 cb185-50 x cb185-60 cb185-70 x cb185-80 x cb185-90 cb185-100 x cb185-110 cb185-120 x cb185-135 x cb185-150 x p a r t n o . ( a m p s ) cb185p-25 cb185p-80 cb185p-30 cb185p-90 cb185p-35 cb185p-100 cb185p-40 cb185p-110 cb185p-50 cb185p-120 cb185p-60 cb185p-135 cb185p-70 cb185p-150 cb181f type i high amp waterproof circuit breakers with sems nut installed cb184f type iii high amp waterproof manual reset circuit breakers with sems nut installed cb185 type iii high amp switchable, waterproof, flush-mount manual reset circuit breakers with sems nut installed cb185p type iii high amp switchable, panel mount manual reset circuit breakers with sems nut installed high amp circuit breakers these high amp circuit breakers are typically used in auxiliary and accessory circuits for trucks, buses, rvs and marine applications. all high amp circuit breakers comply with the sae j1117 standard for ignition protection and have applications in battery charger systems and dc audio systems. offered in flush-mount or panel-mount (see chart for amps available). p a r t n o . ( a m p s ) cb187p-25 cb187p-80 cb187p-30 cb187p-90 cb187p-35 cb187p-100 cb187p-40 cb187p-110 cb187p-50 cb187p-120 cb187p-60 cb187p-135 cb187p-70 cb187p-150 cb187p type iii marine-rated panel-mount manual reset circuit breaker with switch function marine-rated circuit breakers specifically designed to meet the needs of marine applications, the cb187f and cb187p offer 5ka interrupting ratings and ignition protection per abyc e-11. usable as an on/off switch (capable of withstanding 3000 on/off cycles @48vdc), they have corrosion resistant plating on 5 / 16 -18 copper terminals. cb187f type iii marine-rated surface-mount manual reset circuit breaker with switch function p a r t n o . ( a m p s ) cb187f-25 cb187f-80 cb187f-30 cb187f-90 cb187f-35 cb187f-100 cb187f-40 cb187f-110 cb187f-50 cb187f-120 cb187f-60 cb187f-135 cb187f-70 cb187f-150 cb251 type i ignition protected weatherproof panel-mount manual reset circuit breaker, 32vdc p a r t n o . ( a m p s ) cb255-10 cb255-30 cb255-15 cb255-35 cb255-20 cb255-40 cb255-25 cb255-50 cb255 type iii ignition protected weatherproof panel-mount manual reset circuit breaker with push-to-trip option, 32vdc p a r t n o . ( a m p s ) cb251-10 cb251-30 cb251-15 cb251-35 cb251-20 cb251-40 cb251-25 cb251-50


▲Up To Search▲   

 
Price & Availability of CBT-15N

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X